Post by mingwang » May 14th, 2019, 6:52 am

Dear all,

I have a question on particle dry deposition.

I am aware that Particle Diameter (um), Density (g/cc) and Shape will be overridden by a fixed value for Vel (m/s).

Do we have to input a value for Vel (m/s)?

Would it be all right to just give a value for Particle Diameter (um), Density (g/cc) and Shape, if I want to include dry deposition in my dispersion simulation?

Your help would be much appreciated. Thanks. :)


Kind Regards,

Ming

barbara.stunder
Posts: 324
Joined: November 9th, 2012, 4:23 pm
Registered HYSPLIT User: Yes

Re: Dry Deposition

Post by barbara.stunder » May 20th, 2019, 8:38 am

Please see the help file c:\hysplit4\html\S314.htm

You can get to this from the GUI - Concentration - Setup Run - Pollutant, Deposition and Grids setup - Specie 1 under Deposition, Help

mingwang
Posts: 36
Joined: May 8th, 2019, 9:19 pm
Registered HYSPLIT User: No

Re: Dry Deposition

Post by mingwang » May 21st, 2019, 1:51 am

Thank you very much for your help, barbara.stunder. :)