Hi,

I have tried to use variable emissions with efile and I have generated a EMITIMES with 8 hours of variable emission. This is my file:


YYYY MM DD HH DURATION(hhhh) #RECORDS
YYYY MM DD HH MM DURATION(hhmm) LAT LON HGT(m) RATE(/h) AREA(m2) HEAT(w)
2013 10 11 12 9999 01
2013 10 11 12 00 0100 40.2299 -05.9475 36.40 560.57 0.0 0.0
2013 10 11 13 9999 01
2013 10 11 13 00 0100 40.2299 -05.9475 36.40 19.57 0.0 0.0
2013 10 11 14 9999 01
2013 10 11 14 00 0100 40.2299 -05.9475 36.40 20.00 0.0 0.0
2013 10 11 15 9999 01
2013 10 11 15 00 0100 40.2299 -05.9475 36.40 25.00 0.0 0.0
2013 10 11 16 9999 01
2013 10 11 16 00 0100 40.2299 -05.9475 36.40 26.00 0.0 0.0
2013 10 11 17 9999 01
2013 10 11 17 00 0100 40.2299 -05.9475 36.40 100.00 0.0 0.0
2013 10 11 18 9999 01
2013 10 11 18 00 0100 40.2299 -05.9475 36.40 200.00 0.0 0.0

I have run hysplit but after two hours, at 15.00 ,16.00, 17.00 and 18.00 the output concentration is zero, and I have tried different methods… I don’t know which could be the problem with my configuration because this output is not possible with my emissions. I have checked the message file but I couldn’t find solution. Would be possible that hysplit model hasn’t read emission after 12.00 hour?
ariel.stein
Posts: 660
Joined: November 7th, 2012, 2:14 pm
Registered HYSPLIT User: Yes

Re: Variable emission and output zero

Post by ariel.stein »

Can you please send me your CONTROL file?
aolidr
Posts: 3
Joined: May 6th, 2014, 6:18 am
Registered HYSPLIT User: No

Re: Variable emission and output zero

Post by aolidr »

I am going to send you emission file and control file. I posted an example as mine.
Attachments
working.zip
control and emitimes
(613 Bytes) Downloaded 419 times
ariel.stein
Posts: 660
Joined: November 7th, 2012, 2:14 pm
Registered HYSPLIT User: Yes

Re: Variable emission and output zero

Post by ariel.stein »

The problem is in your meteorological file. Do you have enough hours to cover the duration of the run? or you just have a couple of hours in the file?
aolidr
Posts: 3
Joined: May 6th, 2014, 6:18 am
Registered HYSPLIT User: No

Re: Variable emission and output zero

Post by aolidr »

I have tried to run another hours without variable emission file and I got values different from zero. I have though it could be the file or the format. Could I need to change configuration of my computer ? or to change something in the EMITIMES file (space or ..) . Because hysplit model reads and understands the file because the output for the first hour is the same with and without the file, but next hours are the problem.....

Thanks in advance.
ariel.stein
Posts: 660
Joined: November 7th, 2012, 2:14 pm
Registered HYSPLIT User: Yes

Re: Variable emission and output zero

Post by ariel.stein »

Please change your duration in the EMITIMES file from 9999 to 0001.