Input Control file error

Post questions, comments and links to research (research papers, web sites, etc) involving HYSPLIT and atmospheric dust. This section is also to facilitate collaborations between researchers involved in dust transport and dispersion.
Post Reply
Omar Noaman
Posts: 9
Joined: August 22nd, 2022, 9:48 am
Registered HYSPLIT User: No

Input Control file error

Post by Omar Noaman »

Dear Sir
when I tried to calculate the dust storm model for specific archive meteorological data (gdas1.oct19.w3), I received this message error (input control file requires 3 locations, however, I insert only one location which is Baghdad coordinates ), how can I fix this issue?
sonny.zinn
Posts: 377
Joined: May 8th, 2019, 1:31 pm
Registered HYSPLIT User: Yes

Re: Input Control file error

Post by sonny.zinn »

Please attach your SETUP.CFG, CONTROL, and MESSAGE file to this thread. They would be helpful to diagnose the issue.
Omar Noaman
Posts: 9
Joined: August 22nd, 2022, 9:48 am
Registered HYSPLIT User: No

Re: Input Control file error

Post by Omar Noaman »

where can I usually find these files in HYSPLIT, are they under working directory Folder ?
sonny.zinn
Posts: 377
Joined: May 8th, 2019, 1:31 pm
Registered HYSPLIT User: Yes

Re: Input Control file error

Post by sonny.zinn »

If you are using the HYSPLIT Graphical User Interface, the HYSPLIT files should be found in the working directory.
Omar Noaman
Posts: 9
Joined: August 22nd, 2022, 9:48 am
Registered HYSPLIT User: No

Re: Input Control file error

Post by Omar Noaman »

Dear zinn, unfortunately, I tried hard to upload the file but every time I received this error message invalid file extension during uploading files.
sonny.zinn
Posts: 377
Joined: May 8th, 2019, 1:31 pm
Registered HYSPLIT User: Yes

Re: Input Control file error

Post by sonny.zinn »

You might want to rename CONTROL to CONTROL.txt, SETUP.CFG to SETUP.txt, etc. and try uploading them again.
Omar Noaman
Posts: 9
Joined: August 22nd, 2022, 9:48 am
Registered HYSPLIT User: No

Re: Input Control file error

Post by Omar Noaman »

Dear zinn
here is the message error

Input CONTROL file requires exactly 3 locations:
1: lower left corner of matrix grid (1,1)
2: upper right corner of matrix grid (imax,jmax)
3: location of grid point (2,2) adjacent to (1,1)
Enter to continue ...
forrtl: The pipe has been ended.

forrtl: severe (24): end-of-file during read, unit -4, file CONIN$
Image PC Routine Line Source
dustbdy.exe 00007FF7037EE308 Unknown Unknown Unknown
dustbdy.exe 00007FF7037CE756 Unknown Unknown Unknown
dustbdy.exe 00007FF7037B15A4 Unknown Unknown Unknown
dustbdy.exe 00007FF703846632 Unknown Unknown Unknown
dustbdy.exe 00007FF7038469C0 Unknown Unknown Unknown
KERNEL32.DLL 00007FFA14EA7C24 Unknown Unknown Unknown
ntdll.dll 00007FFA16A0D721 Unknown Unknown Unknown
Input CONTROL file requires exactly 3 locations:
1: lower left corner of matrix grid (1,1)
2: upper right corner of matrix grid (imax,jmax)
3: location of grid point (2,2) adjacent to (1,1)
Enter to continue ...
forrtl: The pipe has been ended.

forrtl: severe (24): end-of-file during read, unit -4, file CONIN$
Image PC Routine Line Source
dustbdy.exe 00007FF7037EE308 Unknown Unknown Unknown
dustbdy.exe 00007FF7037CE756 Unknown Unknown Unknown
dustbdy.exe 00007FF7037B15A4 Unknown Unknown Unknown
dustbdy.exe 00007FF703846632 Unknown Unknown Unknown
dustbdy.exe 00007FF7038469C0 Unknown Unknown Unknown
KERNEL32.DLL 00007FFA14EA7C24 Unknown Unknown Unknown
ntdll.dll 00007FFA16A0D721 Unknown Unknown Unknown
while executing
"exec $exec_dir/dustbdy.exe"
(procedure "Conc_run" line 31)
invoked from within
"Conc_run hycs_std D"
(menu invoke)
sonny.zinn
Posts: 377
Joined: May 8th, 2019, 1:31 pm
Registered HYSPLIT User: Yes

Re: Input Control file error

Post by sonny.zinn »

Thanks for posting the MESSAGE file content. We will need CONTROL and SETUP.CFG files as well.
Omar Noaman
Posts: 9
Joined: August 22nd, 2022, 9:48 am
Registered HYSPLIT User: No

Re: Input Control file error

Post by Omar Noaman »

Dear zinn
The attachment includes control and setup_mod_CFG after converting to text files
Best Regards
Attachments
CONTROL.txt
(291 Bytes) Downloaded 72050 times
SETUP_mod.CFG.txt
(388 Bytes) Downloaded 71939 times
sonny.zinn
Posts: 377
Joined: May 8th, 2019, 1:31 pm
Registered HYSPLIT User: Yes

Re: Input Control file error

Post by sonny.zinn »

Your CONTROL file specifies one release location on lines 2-3. For the dustbdy program to work, the CONTROL file must have three locations: see https://www.ready.noaa.gov/hysplitusers ... m#run_dust.
Post Reply

Return to “Dust”