Search found 130 matches

by Fantine
June 24th, 2020, 9:18 am
Forum: 11. Pollutant transformations and deposition
Topic: 11.2 captex_control.txt will not retrieve
Replies: 1
Views: 73

Re: 11.2 captex_control.txt will not retrieve

Try to reset and close the model. When you restart it, retrieve control and setup files again.
And this post may be helpful: viewtopic.php?f=46&t=1898&p=5632&hilit=retrieve#p5632
by Fantine
June 24th, 2020, 8:29 am
Forum: 14. Wildfire smoke and dust storms
Topic: Download of dust storm data failed
Replies: 2
Views: 92

Re: Download of dust storm data failed

Try to go to the workshop page for downloading the data: https://www.ready.noaa.gov/register/HYS ... agenda.php
The links are under a subtitle "The NOAA Air Resources Laboratory website".
by Fantine
June 23rd, 2020, 4:40 pm
Forum: 11. Pollutant transformations and deposition
Topic: FMDV details
Replies: 3
Views: 113

Re: FMDV details

For the parameters of deposition, you can look at the user guide: https://www.ready.noaa.gov/hysplitusersguide/S314.htm
by Fantine
June 23rd, 2020, 4:33 pm
Forum: 11. Pollutant transformations and deposition
Topic: FMDV details
Replies: 3
Views: 113

Re: FMDV details

You can go to the HYSPLIt users guide for more info about FMDV using HYSPLIT: https://ready.arl.noaa.gov/hysplitusersguide/S419.htm
by Fantine
June 23rd, 2020, 2:38 pm
Forum: HYSPLIT for PCs
Topic: Unable to run HYSPLIT software after Installation
Replies: 1
Views: 99

Re: Unable to run HYSPLIT software after Installation

Hi, did you follow the tutorial for installation? https://www.ready.noaa.gov/documents/Tutorial/html/install_win.html Please check if you have all the tools (step 1-4) installed successfully before installing HYSPLIT. And this recording of the tutorial may be helpful for you: https://www.ready.noaa....
by Fantine
June 23rd, 2020, 2:31 pm
Forum: 8. Configuring the CAPTEX simulation
Topic: Error: invalid command name ".f.f.text"
Replies: 5
Views: 112

Re: Error: invalid command name ".f.f.text"

You can just close the error message box and move on. It seems if you click the "exit" button immediately after "Analyze", the error box will come out because the program is not done yet. Wait for a few more seconds to click the "exit" button. A "beep" sound will let you know it is finished. We trie...
by Fantine
June 23rd, 2020, 2:14 pm
Forum: 8. Configuring the CAPTEX simulation
Topic: Error: invalid command name ".f.f.text"
Replies: 5
Views: 112

Re: Error: invalid command name ".f.f.text"

My colleague, Allison who runs HYSPLIT on a Macbook, can reproduce the error you had and is working on this. We will keep you posted. Thanks for your patience. Please move forward to other sections and we will come back on this later.
by Fantine
June 23rd, 2020, 1:36 pm
Forum: 8. Configuring the CAPTEX simulation
Topic: Error: invalid command name ".f.f.text"
Replies: 5
Views: 112

Re: Error: invalid command name ".f.f.text"

I followed what you mentioned in the post but was not able to reproduce the error you had.
I suggest you click "reset" and follow section 8.5 again - loading captex_control.txt and captex_setup.txt, and then change the particle number and run the test. Let us know if you still have a problem on this.
by Fantine
June 23rd, 2020, 1:23 pm
Forum: 8. Configuring the CAPTEX simulation
Topic: concplot.ps not found
Replies: 1
Views: 55

Re: concplot.ps not found

Not quite sure what your question is.
Maybe this post can help you diagnose the problem you encounter: viewtopic.php?f=44&t=1889
by Fantine
June 23rd, 2020, 1:01 pm
Forum: 7. Air concentration calculations
Topic: concplot error at display
Replies: 5
Views: 113

Re: concplot error at display

The "concentration display" menu takes the hypslit output file (hysplit2.bin in the example below), generates a ps file (concplot.ps), and then displays it. The error message "concplot not found" means the program failed to generate concplot.ps. Please check again if the HYSPLIT run was done success...