Search found 9 matches

by AnuvA
March 16th, 2024, 4:28 am
Forum: Dispersion Model
Topic: Pollutant Concentration
Replies: 1
Views: 556

Pollutant Concentration

Dear all, I have 2 weeks hourly air pollutants concentration data for a location. The data were collected by air quality monitoring station. Is that possible to develop dispersion model using HYSPLIT for these data. If possible please recommend a/few paper/s.
by AnuvA
December 2nd, 2022, 12:41 am
Forum: Dispersion Model
Topic: Ozone Distribution Simulation
Replies: 0
Views: 36608

Ozone Distribution Simulation

Would anyone can help me with the below query?

"Can we use HYSPLIT Model to simulate the Ozone distribution in atmosphere? If not why?"
by AnuvA
November 8th, 2022, 10:30 am
Forum: Dispersion Model
Topic: Calibration
Replies: 1
Views: 12314

Re: Calibration

Is there any suggestion? I have searched few but any comments will be a great help for me.
by AnuvA
August 31st, 2022, 3:48 am
Forum: Dispersion Model
Topic: Calibration
Replies: 1
Views: 12314

Calibration

Hello All, I am collecting pollutant concentrations from three different locations of three different countries. I have found in the tutorial that the height was taken as 100m for pollutant. Is there any recommendation regarding placement of the monitoring equipment? However, I am not sure whether m...
by AnuvA
August 29th, 2022, 7:16 am
Forum: Users
Topic: Error message in Air Concentration run
Replies: 4
Views: 14590

Re: Error message in Air Concentration run

Thanks a lot.......
by AnuvA
August 20th, 2022, 11:54 am
Forum: Users
Topic: Error message in Air Concentration run
Replies: 4
Views: 14590

Re: Error message in Air Concentration run

Thank you for your reply. I have tried to get the .bin gfs meteorological data via the link given but it is not working. Instead, I have got one link https://www.nco.ncep.noaa.gov/pmb/products/gfs/ but I have not find any meteorological file here. Then, I have tried through ftp client FileZilla but ...
by AnuvA
August 18th, 2022, 11:36 pm
Forum: Users
Topic: Error message in Air Concentration run
Replies: 4
Views: 14590

Error message in Air Concentration run

I used the Hysplit for Air Concentration for a single pollutant. I used the starting time of simulation as 31 May 2022, 12 hrs. After running this I have received the attached error message. For meteorological data I used captex2_gblr.bin as the location is Japan. I have few queries regarding this. ...
by AnuvA
August 18th, 2022, 11:19 pm
Forum: Users
Topic: Pollutant Concentration Modeling
Replies: 2
Views: 7031

Re: Pollutant Concentration Modeling

Thank you Alicec for your reply.......
by AnuvA
May 15th, 2022, 8:04 am
Forum: Users
Topic: Pollutant Concentration Modeling
Replies: 2
Views: 7031

Pollutant Concentration Modeling

Hello, I have six air pollutant concentrations for 42 locations measured by onsite monitoring station in Bangladesh for a proposed rail alignment. Is that possible to model the present condition of these pollutants using Hysplit? How to put the initial concentration values in the model?