Thank you for your explanation.
I misinterpreted the description given in the manual and thought that long-term dose calculation is only applied to the deposition doses i.e. the cloudshine doses are left as they are after the original calculation even if long-term doses calculation is applied. I ...
Search found 2 matches
- July 10th, 2020, 8:48 am
- Forum: Radiological
- Topic: Long-term dose estimation with con2rem
- Replies: 2
- Views: 61278
- July 2nd, 2020, 7:48 am
- Forum: Radiological
- Topic: Long-term dose estimation with con2rem
- Replies: 2
- Views: 61278
Long-term dose estimation with con2rem
Hysplit version: April 2018 release (SVN 951)
OS: WIN10
I am running a 48 h simulation where I-131 (particulate form) is released hourly during the first 24 h. I am trying to estimate the doses related to this release with a one year integration time. If I have understood correctly con2rem does ...
OS: WIN10
I am running a 48 h simulation where I-131 (particulate form) is released hourly during the first 24 h. I am trying to estimate the doses related to this release with a one year integration time. If I have understood correctly con2rem does ...