- April 29th, 2020, 9:22 am
- Forum: Trajectory Model
- Topic: Output Frequency < 1 Minute
- Replies: 2
- Views: 2303
Re: Output Frequency < 1 Minute
Thank you.
- April 1st, 2020, 4:07 pm
- Forum: HYSPLIT for PCs
- Topic: Error Generating KML
- Replies: 1
- Views: 2377
Error Generating KML
After my run successfully finishes I"m getting an error when trying to generate KML output. Here's the error message: Started Trajectory Drawing Last Changed Rev: 1039 Last Changed Date: 2019-08-09 12:00:00 -0500 (Fri, 9 August 2019) *ERROR* tm2min: year out of valid range (1941-2040) - 405 900 Star...
- April 1st, 2020, 3:54 pm
- Forum: Trajectory Model
- Topic: Output Frequency < 1 Minute
- Replies: 2
- Views: 2303
Output Frequency < 1 Minute
I'm trying to provide HYSPLIT with data (converted from wrfout files to ARL format) at each model time step, which is every 6 seconds. Is there anyway to get output for HYSPLIT trajectories every 6 seconds (or something less than 1 minute). I was able to provide it input at 1 minute intervals and ge...