Search found 18 matches

by bektas61
March 23rd, 2020, 8:25 am
Forum: Users
Topic: Deposition and Dose Calculation
Replies: 3
Views: 6634

Re: Deposition and Dose Calculation

Thanks a lot for all the detailed answers. I really appreciate it :)
Best regards.
by bektas61
March 12th, 2020, 2:43 pm
Forum: Users
Topic: Deposition and Dose Calculation
Replies: 3
Views: 6634

Deposition and Dose Calculation

Hi everyone, I have a few questions about deposition and dose calculations that are related to each other as followed; 1- Is it possible to examine wet deposition by using user-entered data? I tried it but not allowed due to the precipitation rate that is given as an error message. However, when ı c...
by bektas61
March 12th, 2020, 2:17 pm
Forum: Users
Topic: Meteorological Data Information
Replies: 2
Views: 3504

Re: Meteorological Data Information

It is solved by analyzing data, thanks for your help :)
by bektas61
March 4th, 2020, 9:13 am
Forum: Users
Topic: Meteorological Data Information
Replies: 2
Views: 3504

Meteorological Data Information

Hi everyone, When ı figured out meteorological data information of captex2_narr.bin file, I little confused because of the vertical level data. The data divided into 20 groups vertically but pressure values inconsistent with geopotential height values as illustrated in Fig.1. q2.png I also wonder me...
by bektas61
December 26th, 2019, 3:49 pm
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 4045

Re: Single Particle Animation Error

Thanks Barbara It was solved. The problem caused by installation issues. I would install to imagemagick program before the ghostview. that was the reason why it did not read the postscript file and convert it as .gif file. It was installed different way to show differeces. you know sometimes startin...
by bektas61
December 20th, 2019, 10:09 am
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 4045

Re: Single Particle Animation Error

Yes, I am saying I got the same error both of the following in the "Set directories" convert.exe C:/Program Files/ImageMagick-7.0.8-Q16/convert.exe (attacment4) It is tried as your descriptions but the result did not change. yes the postscript file is "concplot.ps" But ı read more things in the help...
by bektas61
December 18th, 2019, 9:34 am
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 4004

Re: Reconfiguring Test Case Misleading

I understood, thanks a lot for your clarification.
I really appreciate it :)
Best regards.
by bektas61
December 11th, 2019, 1:37 pm
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 4045

Single Particle Animation Error

Hi, everyone, I have a question about Single Particle Animation. To see all the frames in a single animated graphic, similar to a trajectory, pressed the Concentration / Utilities / Postscript to Image menu tab to open the ImageMagick conversion menu. I selected the Animate button as in attachment1 ...
by bektas61
December 11th, 2019, 9:41 am
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 4004

Re: Reconfiguring Test Case Misleading

Attachments uploaded respectivly as ı mentioned above.
by bektas61
December 10th, 2019, 2:35 pm
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 4004

Reconfiguring Test Case Misleading

Hi everyone, ı have jus started tutorial 7 "Air Concentration Calculations" and for 7.1 Reconfiguring the test case. I opened the Hysplit4 and pressed Concentration / Setup Run saved, run model, displayed and took the same result as in tutorial(attacment1). But when ı wanna carry out the second case...

Go to advanced search