Search found 14 matches

by bektas61
December 26th, 2019, 3:49 pm
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 80

Re: Single Particle Animation Error

Thanks Barbara It was solved. The problem caused by installation issues. I would install to imagemagick program before the ghostview. that was the reason why it did not read the postscript file and convert it as .gif file. It was installed different way to show differeces. you know sometimes startin...
by bektas61
December 20th, 2019, 10:09 am
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 80

Re: Single Particle Animation Error

Yes, I am saying I got the same error both of the following in the "Set directories" convert.exe C:/Program Files/ImageMagick-7.0.8-Q16/convert.exe (attacment4) It is tried as your descriptions but the result did not change. yes the postscript file is "concplot.ps" But ı read more things in the help...
by bektas61
December 18th, 2019, 9:34 am
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 60

Re: Reconfiguring Test Case Misleading

I understood, thanks a lot for your clarification.
I really appreciate it :)
Best regards.
by bektas61
December 11th, 2019, 1:37 pm
Forum: HYSPLIT for PCs
Topic: Single Particle Animation Error
Replies: 6
Views: 80

Single Particle Animation Error

Hi, everyone, I have a question about Single Particle Animation. To see all the frames in a single animated graphic, similar to a trajectory, pressed the Concentration / Utilities / Postscript to Image menu tab to open the ImageMagick conversion menu. I selected the Animate button as in attachment1 ...
by bektas61
December 11th, 2019, 9:41 am
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 60

Re: Reconfiguring Test Case Misleading

Attachments uploaded respectivly as ı mentioned above.
by bektas61
December 10th, 2019, 2:35 pm
Forum: Users
Topic: Reconfiguring Test Case Misleading
Replies: 3
Views: 60

Reconfiguring Test Case Misleading

Hi everyone, ı have jus started tutorial 7 "Air Concentration Calculations" and for 7.1 Reconfiguring the test case. I opened the Hysplit4 and pressed Concentration / Setup Run saved, run model, displayed and took the same result as in tutorial(attacment1). But when ı wanna carry out the second case...
by bektas61
December 6th, 2019, 9:00 am
Forum: Users
Topic: Internal Server Error Issue
Replies: 2
Views: 563

Re: Internal Server Error Issue

thanks it works :)
by bektas61
December 6th, 2019, 8:57 am
Forum: General questions on meteorological data needed for HYSPLIT
Topic: HYSPLIT meteororlogical data files
Replies: 2
Views: 391

Re: HYSPLIT meteororlogical data files

I gave my answers.
Thank you for your recommendations.
by bektas61
December 6th, 2019, 8:21 am
Forum: General questions on meteorological data needed for HYSPLIT
Topic: HYSPLIT meteororlogical data files-Q 4,5
Replies: 2
Views: 584

Re: HYSPLIT meteororlogical data files-Q 4,5

I did somethings wrong than fixed and it is solved.
I really appreciate for reply. Thank you so much.
Best regards, :)
by bektas61
November 25th, 2019, 9:16 am
Forum: General questions on meteorological data needed for HYSPLIT
Topic: HYSPLIT meteororlogical data files-Q 4,5
Replies: 2
Views: 584

HYSPLIT meteororlogical data files-Q 4,5

Hi everyone, ı am new to HYSPLIT code but ı have watched and read the tutorials for a long time and ı also tested a few examples then I got several questions about HYSPLIT meteorological data files waiting for the answers. 4-) I created a user-entered meteorological file which is identical with the ...