Search found 30 matches

by rotendd
February 5th, 2020, 11:25 am
Forum: Dispersion Model
Topic: 'cdump' is empty
Replies: 4
Views: 3437

Re: 'cdump' is empty

Sorry for the delay! I don't always get notifications when admins respond to my posts. Attached is my MESSAGE file.
by rotendd
January 23rd, 2020, 5:21 pm
Forum: Dispersion Model
Topic: 'cdump' is empty
Replies: 4
Views: 3437

Re: 'cdump' is empty

I should add that I'm generating these files with an R wrapper that I have written a few years ago. This method has been successful in the past but recent "tweaks" I have made are putting me in this situation...
by rotendd
January 22nd, 2020, 6:32 pm
Forum: Dispersion Model
Topic: 'cdump' is empty
Replies: 4
Views: 3437

'cdump' is empty

I'm using the hycs_std.exe file with CONTROL, EMITIMES, CONC.CFG, SETUP.CFG, and ASCDATA.CFG in the same working directory as the exe file. hycs_std.exe runs and reaches "100% complete" but the output file (TEST-20120101-0101) is always empty (144B). Using the con2asc.exe file afterwards returns not...
by rotendd
May 20th, 2018, 5:24 pm
Forum: Dispersion Model
Topic: Gaussian/Top Hat model parameters
Replies: 16
Views: 14094

Re: Gaussian/Top Hat model parameters

Excellent! My apologies for a slow response. It's the end of a semester :-) In regards to your additional questions: 1. How big is your concentration grid? It could be that some of the puffs/particles are moving off the concentration grid (either horizontally or vertically). I receive no warnings ab...
by rotendd
April 20th, 2018, 6:40 pm
Forum: Dispersion Model
Topic: Gaussian/Top Hat model parameters
Replies: 16
Views: 14094

Re: Gaussian/Top Hat model parameters

In regards to the comparison, I'm essentially gridding the cdump files and adding the average concentrations in each grid cell. (The grids cells are uniform in size.) I'm using this as an analog for mass. If I only change a single parameter (release height, release temp, etc.), I can use the same me...
by rotendd
April 16th, 2018, 3:09 pm
Forum: Dispersion Model
Topic: Gaussian/Top Hat model parameters
Replies: 16
Views: 14094

Re: Gaussian/Top Hat model parameters

First off, thanks again for your previous help! I have a few more directed questions. I am conducting a sensitivity analysis by comparing two different scenarios: A 24-hour dispersion from a source of small area (Area is included in EMITIMES file) The same source modeled as a point source (Area = 0m...
by rotendd
March 2nd, 2018, 3:43 pm
Forum: Dispersion Model
Topic: With or Without EMITIMES?
Replies: 3
Views: 3870

Re: With or Without EMITIMES?

If there are no values for release height, release area, etc. in the CONTROL file, HYSPLIT will still run. In this case, does it use 0m AGL for the release height and 0m^2 for the release area? Does it assign a heat value (in Watts) to the source even when a value is NOT included in the EMITIMES or ...
by rotendd
February 18th, 2018, 1:43 pm
Forum: Dispersion Model
Topic: With or Without EMITIMES?
Replies: 3
Views: 3870

With or Without EMITIMES?

If the EMITIMES file allows multiple release points as well as respective heights, release areas, and temperatures, what does the model assume these parameters are WITHOUT an EMITIMES file? I'm assuming they default to zero. This this correct?
by rotendd
July 24th, 2017, 12:30 am
Forum: Dispersion Model
Topic: Gaussian/Top Hat model parameters
Replies: 16
Views: 14094

Re: Gaussian/Top Hat model parameters

One other (hopefully) quick question... If I use Gh-Pv to 3D particle (initd = 130) and set the conversion time to 0 hours (conage = 0), will a puff of my desired width in the EMITIMES file still be initialized but immediately converted to particles? Or will a value of conage = 0 cause HYSPLIT to ru...
by rotendd
July 21st, 2017, 1:22 pm
Forum: Dispersion Model
Topic: Gaussian/Top Hat model parameters
Replies: 16
Views: 14094

Re: Gaussian/Top Hat model parameters

Your insights are very helpful! In regards to the 0m stack height and the inclusion of stack area, something that I am interested in is how much these values can affect the output results after they have been propagated over a 24hr period. I'm incrementing these values for a handful of different pow...

Go to advanced search